Peristaltic tubing is insulating and so its use should be limited to the
length adjacent to the pumphead. Earthed, conductive pipework
should be used elsewhere in the system.
8.3
Pump installation
For a correctly engineered installation please ensure that the following guidelines are followed:
l
Do
not build a pump into a tight location without adequate airflow around the pump.
l
Do
keep delivery and suction tubes as short and direct as possible and follow the straightest route.
Use bends of large radius: at least four times the tubing diameter. Ensure that connecting pipework
and fittings are suitably rated to handle the predicted pipeline pressure. Avoid pipe reducers and
lengths of smaller bore tubing than the pumphead section, particularly in pipelines on the suction
side. Any valves in the pipeline (not usually needed) must not restrict the flow. Any valves in the flow
line must be open when the pump is running.
l
Do
use suction and delivery pipes equal to or larger than the bore of the tube in the pumphead.
When pumping viscous fluids use pipe runs with a bore several times larger than the pump tube.
l
Do
ensure that your system fluid supply and discharge pipework is suitable for the hazardous
environment in which the pump is operating and doesn't allow for the accumulation of electrostatic
charge.
l
Do
site the pump at or just below the level of the fluid to be pumped if possible. This will ensure
flooded suction and maximum pumping efficiency.
l
Do
keep the pumphead track and all moving parts clean and free from contamination and debris.
l
Do
run at slow speed when pumping viscous fluids. Flooded suction will enhance pumping
performance in all cases, particularly for materials of a viscous nature.
l
Do
limit peristaltic tubing to the length adjacent to the pumphead because peristaltic tubing is
insulating. Electrostatic testing has been used to determine which Watson-Marlow tubing is suitable
for use in hazardous environments. See section 12 "Special conditions of use for safe operation -
Tube materials suitable for use with this equipment" on page 22 for more information. Earthed,
conductive pipework should be used elsewhere in the system.
l
When using Marprene or Bioprene
continuous tubing, do re-tension the tube after the first 30
minutes of running.
l
If unsure of an installation please contact your local Watson- Marlow representative for further
assistance.
l
Tube selection:
The chemical compatibility lists published in Watson- Marlow publications are
guides. If in doubt about the compatibility of a tube material and the duty fluid, request a Watson-
Marlow tube sample card for immersion trials.
PB0346:m-501atex-en-03
18
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Summary of Contents for 053.0001.A00
Page 1: ...Watson Marlow 501RLA ATEX Pumphead User Manual m 501atex 03 PB0346 3 ...
Page 5: ...Blank Page ...
Page 45: ...Blank Page ...
Page 87: ...Blank Page ...
Page 125: ...Blank Page ...
Page 129: ...Blank Page ...
Page 171: ...Blank Page ...
Page 209: ...Blank Page ...
Page 213: ...Blank Page ...
Page 255: ...Blank Page ...
Page 297: ...Blank Page ...
Page 335: ...Blank Page ...
Page 361: ...29 PB0346 m 501atex ko 03 l 가드를 해제하십시오 l 위 순서의 역순으로 펌프헤드에서 튜빙을 분리합니다 ...
Page 371: ...39 PB0346 m 501atex ko 03 Blank Page ...
Page 375: ...Blank Page ...
Page 413: ...Blank Page ...
Page 449: ...39 PB0346 m 501atex da 03 Blank Page ...
Page 453: ...Blank Page ...
Page 497: ...Blank Page ...
Page 533: ...39 PB0346 m 501atex sv 03 Blank Page ...
Page 537: ...Blank Page ...
Page 575: ...Blank Page ...