Pedestal Sump 

Pump

FLOAT INSTALLATION SPV800, SPV500 
& SSPTU50

1.   To attach float for SPV800, SPV500 

& SSPTU50. insert float rod through 
hole in switch lever. 

2.   Place rubber grommet on float rod 

in temporary position.

3.   Slide float guide onto float rod.
4.   Using pliers to hold the float rod, 

screw the float on.

5.  Attach the float guide to pump 

halfway up the pumps stand and 
properly align with motor switch.

FLOAT INSTALLATION PTU30, PTU33A 
& PTU50

1.   To attach float for PTU30, PTU33A, and 

PTU50 begin by sliding  the float guide 
onto the open end of the float rod.

2.   Next slide a grommet onto the open 

end of the float rod about ¼ of the 
way down.

3.   Guide the open end of the float rod 

through the hole in the switch lever.

4.   Place the second grommet onto the 

open end of the float rod, being sure 
to keep the float rod inserted into the 
switch lever.

5.  Attach the float guide to pump halfway 

up the pumps stand and properly align 
with motor switch.

NOTE:

  For all replacement float kits 

installation will be the same as for 
SPV800, SPV500 & SSPTU50.

GENErAL SAFETy INFOrMATION

Read these rules and 
instructions carefully. Failure 
to follow these instructions 
could cause serious bodily 
injury and/or property damage.

 

Do not submerge 

  motor or allow 

motor to be exposed to water. Personal 
injury and/or death could result.
 

Do not  

  use to 

pump flammable or explosive 
fluids such as gasoline, fuel 
oil, kerosene, etc. Do not 
use in a flammable and/or explosive 
atmosphere. Pump should only be used 
to pump clear water. Personal injury 
and/or death could result.
 

This pump is not 

  designed to handle 

salt water, brine, laundry discharge or 
any other application which may contain 
caustic chemicals and/or foreign materials. 
Pump damage could occur if used in these 
applications and will void warranty.
 

All wiring must be  

  performed by a 

qualified electrician.
 

If the  

  basement 

has water or moisture on the 
floor, do not walk on wet area 
until all power is turned off. If 
the shut-off box is in the basement, call 
an electrician to disconnect the power. 
Remove pump and either repair or replace. 
Failure to follow this warning could result 
in fatal electrical shock.
 

A battery  backup 

  system should be 

used. Please contact your local retailer 
to order an emergency backup system.

Assembly

 

Always 

  disconnect 

the power source before 
attempting to install, service, 
relocate or maintain the pump. 
Never touch sump pump, pump motor, 
water or discharge piping when pump is 
connected to electrical power. Never handle 
a pump or pump motor with wet hands or 
when standing on wet or damp surface or 
in water. Fatal electrical shock could occur.

Description

The pedestal pump is designed for 
home sump applications. The unit is 
equipped with an 8-ft long, 3-prong 
grounding type power cord. Motor is 
air cooled; it is not designed to operate 
under water. A float switch is provided 
for automatic pump operation. This 
pump is not suitable for aquatic life.

Unpacking

Inspect this unit before it is used. 
Occasionally, products are damaged during 
shipment. If the pump or components are 
damaged, return the unit to the place of 
purchase for replacement. Failure to do so 
could result in serious injury or death. Some 
warning labels come affixed to the pump. 
Over time, these labels may fade. If this 
happens, contact Wayne Water Systems for 
a free replacement label.

Safety Guidelines

This manual contains information that is 
very important to know and understand. 
This information is provided for SAFETY 
and to PREVENT EQUIPMENT PROBLEMS. 
To help recognize this information, 
observe the following symbols. 

 

Danger  indicates 

  an imminently 

hazardous situation which, if not avoided, 

will result in death or serious injury.
 

Warning  indicates 

  a potentially 

hazardous situation which, if not avoided, 

could result in death or serious injury.
 

Caution  indicates a  

  potentially hazardous 

situation which, if not avoided, may result 

in minor or moderate injury.
 

Notice  indicates 

  important 

information, that if not followed, may 

cause damage to equipment.

General Safety 

Information

CALIFOrNIA PrOPOSITION 65

 

This product or its 

 

  power cord may 

contain chemicals, including lead, known 
to the State of California to cause cancer 
and birth defects or other reproductive 
harm. Wash hands after handling.

MANUAL

24 in.

Min.

14 in.

Dia.

Min.

Figure 1 

Switch

Grommet

Float Rod

Guide

Float

GFCI Grounded 

Outlet

Summary of Contents for 360516-001

Page 1: ...d will void warranty All wiring must be performed by a qualified electrician If the basement has water or moisture on the floor do not walk on wet area until all power is turned off If the shut off bo...

Page 2: ...do so could cause piping to break pump to fail etc which could result in property damage and or personal injury Flood risk If flexible discharge hose is used make sure pump is secured in sump pit to...

Page 3: ...roduction Drive Harrison OH 45030 Replacement Parts List Ref No Description PTU30 PTU33A SPV500 SPV800 PTU50 SSPTU50 1 Float Kit 57030 001 57030 001 57030 001 57030 001 57030 001 57030 001 2 Volute Ki...

Page 4: ...all indirect or consequential damages or expenses whatsoever is excluded Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of inc...

Page 5: ...produits peut endommager la pompe et annulera la garantie Toute installation des fils doit tre effectu e par un lectricien qualifi Ne pas marcher sur un plancher de soussol trempe ou humide avant de...

Page 6: ...Introduire la fiche de l interrupteur flotteur directement dans une prise de 120 volts Voir Figure 2 Ajustement et Essai 1 Remplir la fosse d eau 2 Ajuster l anneau en caoutchouc dans une position per...

Page 7: ...ange N de Ref Description PTU30 PTU33A SPV500 SPV800 PTU50 SSPTU50 1 N c de flotteur 57030 001 57030 001 57030 001 57030 001 57030 001 57030 001 2 N c de volute 61030 001 61030 001 60057 001 60057 001...

Page 8: ...S OU D PENSES QUOI QUE SE SOIT EST EXCLUS Certaines Provinces n autorisent pas de limitations de dur e pour les garanties implicites ni l exclusion ni la limitation des dommages fortuits ou indirects...

Page 9: ...dando la garant a Todas las conexiones deben ser efectuadas por un electricista calificado Si hay agua o humedad en el piso del s tano no pise el rea mojada hasta que toda la energ a el ctrica haya si...

Page 10: ...ica 60 Hz y 15 A Viene con un cord n de 3 conductores y un enchufe de 3 clavijas de conexi n a tierra 3 Instale la bomba en un pozo de sumidero con el tama o m nimo que se indica Ver Figura 1 Construy...

Page 11: ...e Ref Descripci n PTU30 PTU33A SPV500 SPV800 PTU50 SSPTU50 1 Piezas del flotante 57030 001 57030 001 57030 001 57030 001 57030 001 57030 001 2 Piezas de la voluta 61030 001 61030 001 60057 001 60057 0...

Page 12: ...ALQUIER PERDIDA O RESPONSABILIDAD CIVIL SEA DIRECTA O INDIRECTA COMO CONSECUENCIA DE DA OS SON EXCLUIDAS Algunos estados no permiten l mites en la duraci n de las garant as o no permiten que se limite...

Reviews: