Operating Instructions and Parts Manual

www.waynepumps.com

so that the pump switches on with 
approximately 14” of water in the sump.

3.   While the pump is draining the pit, 

verify that the discharge piping is 
carrying the water to a point several 
feet away from the foundation.

4.   If the pump discharge line is 

exposed to freezing temperature, 
the exposed line must be pitched to 
drain. Trapped water will freeze and 
damage the pump.

Maintenance

 

  Always  

disconnect the electrical 
supply before attempting to 
install, service, relocate or 
perform any maintenance. If the power 
source is out of sight, lock and tag 
in the open (off) position to prevent 
unexpected power application. Failure 
to do so could result in fatal electrical 
shock. Only qualified electricians should 
repair this unit. Improper repair could 
result in fatal electrical shock.

1.   Disassembly of the motor prior to 

expiration of warranty will void the 
warranty.  If repairs are required, see 
troubleshooting chart.

2.   Keep pump inlet clean and free 

of all foreign objects and inspect 
annually.  A clogged inlet will 
damage pump.

3.   Check pump monthly for proper 

operation.  

NOTE:

 A pump that has a tripped 

thermal protector may start suddenly!

Installation

1.   A ground fault circuit interrupter 

(GFCI) is required.

2.   This pump is for use on 120 Volt 

(single phase), 60 hz, 15 amp service 
and is equipped with a 3 conductor 
cord and a 3 prong grounding plug.

3.   Install pump in a sump pit with 

minimum size as shown  (See Figure 
1). Construct sump pit of tile, 
concrete, steel or plastic.

4.   Locate unit on a solid, level 

foundation. Do not place pump 
directly on clay, earth, gravel or 
sandy surface. These surfaces contain 
small stones, gravel, sand, etc. that 
may clog or damage the pump and 
cause pump failure (See Figure 1).

5.   (Optional) Thread check valve (not 

included) into pump body carefully 
to avoid stripping or cross threading. 
Do not use pipe joint sealant.

6.   Connect 1-1/4” rigid pipe to rubber 

boot on check valve. Reverse boot 
for 1-1/2” diameter pipe. Tighten 
hose clamps. 

 

Support  pump and 

  piping when 

assembling and after installation. Failure 
to do so could cause piping to break, pump 
to fail, etc. which could result in property 
damage and/or personal injury.
 

Flood  risk. If  

  flexible discharge 

hose is used, make sure pump is 
secured in sump pit to prevent 
movement. Failure to secure pump 
could allow pump movement and switch 
interference and prevent pump from 
starting or stopping.

IMPOrTANT

: Make sure there is 

adequate room for float switch to move 
freely during operation.
7.   Protect electrical cord from sharp 

objects, hot surfaces, oil and 
chemicals. Avoid kinking the 
cord and replace damaged cords 
immediately.

8.   A sump pit cover must be installed 

to prevent debris from clogging or 
damaging the pump.

 

Risk of  

  electrical 

shock! This pump is supplied 
with a grounding conductor 
and grounding type attachment plug. Use 
a grounded GFCI receptacle to reduce the 
risk of fatal electrical shock.

Never cut off the round grounding 
prong. Cutting the cord or plug will 
void the warranty and make the 
pump inoperable.

9.   Insert the float switch cord plug 

directly into a 120 volt outlet (See 
Figure 2).

ADjUST AND T EST

1.   Fill sump with water.
2.   Adjust rubber grommet into a 

permanent position on float rod 

Troubleshooting Chart

Symptom

Possible Cause(s)

Corrective Action

Pump will not start or 
run

1.  Blown fuse
2.  Low line voltage
3.  Defective motor
4.  Defective switch
5.  Impeller
6.  Float obstructed

1.  If blown, replace with proper sized fuse or reset breaker

2.  If voltage is under 108 volts, check wiring size  

- DO NOT USE AN EXTENSION CORD

3.  Replace motor or pump
4.  Replace switch
5.  If impeller will not turn, remove housing and remove blockage
6.  Make sure float moves freely up and down

Pump start and stops too 
often

1.  Back flow of water from piping
2.  Float out of adjustment

1.  Install or replace check valve (Wayne check valve kit #66005-WYN1)
2.  Adjust grommet

Pump will not shut off 
or thermal protector 
turns off

1.  Defective switch
2.  Obstacle in piping
3.  Float obstructed

1.  Replace switch
2.  Remove pump and clean pump and piping
3.  Make sure float moves freely up and down

Pump operates but 
delivers little or no 
water

1.  Low line voltage 

2.  Plugged impeller

1.  If voltage is under 108 volts, check wiring size 

- DO NOT USE AN EXTENSION CORD

2.  Clean out impeller

Grounding

Blade

Grounded

Outlet

Power

Cord

TEST

RESET

Figure 2

GFCI 

Outlet

Summary of Contents for 360516-001

Page 1: ...d will void warranty All wiring must be performed by a qualified electrician If the basement has water or moisture on the floor do not walk on wet area until all power is turned off If the shut off bo...

Page 2: ...do so could cause piping to break pump to fail etc which could result in property damage and or personal injury Flood risk If flexible discharge hose is used make sure pump is secured in sump pit to...

Page 3: ...roduction Drive Harrison OH 45030 Replacement Parts List Ref No Description PTU30 PTU33A SPV500 SPV800 PTU50 SSPTU50 1 Float Kit 57030 001 57030 001 57030 001 57030 001 57030 001 57030 001 2 Volute Ki...

Page 4: ...all indirect or consequential damages or expenses whatsoever is excluded Some states do not allow limitations on how long an implied warranty lasts or do not allow the exclusions or limitations of inc...

Page 5: ...produits peut endommager la pompe et annulera la garantie Toute installation des fils doit tre effectu e par un lectricien qualifi Ne pas marcher sur un plancher de soussol trempe ou humide avant de...

Page 6: ...Introduire la fiche de l interrupteur flotteur directement dans une prise de 120 volts Voir Figure 2 Ajustement et Essai 1 Remplir la fosse d eau 2 Ajuster l anneau en caoutchouc dans une position per...

Page 7: ...ange N de Ref Description PTU30 PTU33A SPV500 SPV800 PTU50 SSPTU50 1 N c de flotteur 57030 001 57030 001 57030 001 57030 001 57030 001 57030 001 2 N c de volute 61030 001 61030 001 60057 001 60057 001...

Page 8: ...S OU D PENSES QUOI QUE SE SOIT EST EXCLUS Certaines Provinces n autorisent pas de limitations de dur e pour les garanties implicites ni l exclusion ni la limitation des dommages fortuits ou indirects...

Page 9: ...dando la garant a Todas las conexiones deben ser efectuadas por un electricista calificado Si hay agua o humedad en el piso del s tano no pise el rea mojada hasta que toda la energ a el ctrica haya si...

Page 10: ...ica 60 Hz y 15 A Viene con un cord n de 3 conductores y un enchufe de 3 clavijas de conexi n a tierra 3 Instale la bomba en un pozo de sumidero con el tama o m nimo que se indica Ver Figura 1 Construy...

Page 11: ...e Ref Descripci n PTU30 PTU33A SPV500 SPV800 PTU50 SSPTU50 1 Piezas del flotante 57030 001 57030 001 57030 001 57030 001 57030 001 57030 001 2 Piezas de la voluta 61030 001 61030 001 60057 001 60057 0...

Page 12: ...ALQUIER PERDIDA O RESPONSABILIDAD CIVIL SEA DIRECTA O INDIRECTA COMO CONSECUENCIA DE DA OS SON EXCLUIDAS Algunos estados no permiten l mites en la duraci n de las garant as o no permiten que se limite...

Reviews: