17
PB0346:m-501atex-en-03
Prevention and dissipation of electrostatic charge
All Watson-Marlow ATEX rated pumpheads include provision for the prevention and dissipation of
electrostatic charge. In order to dissipate electrostatic charge effectively there must be sufficient electrical
contact between the pumphead and the suitably earthed drive.
It is imperative that the 501 ATEX series pumpheads are earthed by connecting the earth terminal on the
track to earth.
Check the effectiveness of any earth connection by measuring its electrical resistance. The resistance must
not exceed 1 MΩ.
DANGER! - EXPLOSION HAZARD
Failure to ensure dissipation of static may cause fire or explosion.
The resistance from any point on the pumphead guard to the earth
terminal is typically 25 Ohms.
Before commissioning:
•
Test the maximum resistance from any point on the guard to
earth. The resistance must not exceed 1 MΩ.
•
Test the maximum resistance from a metal point on the rotor
assembly to the drive casework. The resistance must not exceed
1 MΩ.
Summary of Contents for 053.0001.A00
Page 1: ...Watson Marlow 501RLA ATEX Pumphead User Manual m 501atex 03 PB0346 3 ...
Page 5: ...Blank Page ...
Page 45: ...Blank Page ...
Page 87: ...Blank Page ...
Page 125: ...Blank Page ...
Page 129: ...Blank Page ...
Page 171: ...Blank Page ...
Page 209: ...Blank Page ...
Page 213: ...Blank Page ...
Page 255: ...Blank Page ...
Page 297: ...Blank Page ...
Page 335: ...Blank Page ...
Page 361: ...29 PB0346 m 501atex ko 03 l 가드를 해제하십시오 l 위 순서의 역순으로 펌프헤드에서 튜빙을 분리합니다 ...
Page 371: ...39 PB0346 m 501atex ko 03 Blank Page ...
Page 375: ...Blank Page ...
Page 413: ...Blank Page ...
Page 449: ...39 PB0346 m 501atex da 03 Blank Page ...
Page 453: ...Blank Page ...
Page 497: ...Blank Page ...
Page 533: ...39 PB0346 m 501atex sv 03 Blank Page ...
Page 537: ...Blank Page ...
Page 575: ...Blank Page ...