04.9
Interval: Interval: 2000 operating hours
Charge air cooler(s)
Check water side of charge air cooler(s)
15.2
The first time check and possible cleaning of the
waterside.
If
in good condition and deposits insignificant: future intervals
4000 running hours.
Injection valves
Inspect injection valves
16.5
Test the opening pressure. Dismantle and clean nozzles.
Check the effective needle lift. Check the springs. Replace
the O-rings. Check the nozzle condition in a test pump.
Recommendation:
Replace the complete injection valves
by new or reconditioned ones.
06.1
Measuring instruments
Checking of gauges
Check pressure and temperature gauges. Replace faulty
ones.
23.1
Governor
Change oil in governor
Change lubricating oil, use governor manual.
02.2.4
22.4
Overspeed trip device
Check function of overspeed trip
22.5
Check function and tripping speed.
22.6
04
Maintenance Schedule
22-9845/III
04 - 6
MD, HF
Summary of Contents for Vasa R22
Page 14: ...Appendix B Welding Precautions 200147 00 4...
Page 42: ...02 Fuel Lubricating Oil Cooling Water 22 9601 02 22 VASA 22...
Page 60: ...03 Start Stop and Operation 22 9632 03 12 VASA 22...
Page 72: ...04 Maintenance Schedule 22 9845 III 04 12 MD HF...
Page 92: ...06 II Adjustments Clearances and Wear limits 22 9601 06 6 VASA 22...
Page 116: ...08 Operating Troubles Emergency Operation 22 9601 08 8 VASA 22...
Page 144: ...11 Crank Mechanism 22 9601 11 18 VASA 22...
Page 156: ...12 Cylinder Head with Valves 22 9601 12 12 VASA 22...
Page 164: ...13 Camshaft Driving Gear 22 9601 13 8 VASA 22...
Page 172: ...14 Valve Mechanism and Camshaft 22 9601 14 8 VASA 22...
Page 183: ...22 200520 Turbocharging and Air Cooling 15 VTR Turbocharger 15 11...
Page 189: ...15 III Turbocharging and Air Cooling 22 8604 15 6 VTR 161 251 Turbochargers...
Page 209: ...17 Fuel system 22 9601 17 8 VASA 22...
Page 229: ...18 Lubricating Oil System 22 9601 18 20 VASA 22...
Page 247: ...19 Cooling Water System 22 9601 19 18 VASA 22...
Page 261: ...21 Starting Air System 22 9601 21 10 VASA 22...