890557_d•en•01.07.2014
We reserve the right to carry out improvements
75
7.2.10.3 Holding time hh:mm
The holding time is used to set how long the comfort functions are to be
disabled after manual operation. The setting range is 00:00 to 24:00 hours.
Manual operation can thereby be performed on the control panel by channel
or group as well as by product or for a local group on the local pushbutton.
Turn the touch wheel to set the value “Holding time hh:mm”. Pressing on the
wheel causes the display to jump to minutes. Set the minutes in the same
manner.
The function button [
Stand.
] sets the holding time to the factory setting.
NOTE
A timer command deletes the manual holding time.
7.2.10.4 Uhe manual operation
options
Function buttons,
touch wheel
With the function buttons and the touch wheel
When a comfort function has triggered a move command, counter-control or
stopping is possible.
When a safety function has been triggered, neither counter-controlling nor
stopping is possible.
Hand-held transmitter
Operation is possible at an time (as long as no safety function has triggered
an alarm), regardless of the view in the display of the control
When a comfort function has triggered a move command, counter-control or
stopping is possible.
When a safety function has been triggered, neither counter-controlling nor
stopping is possible.
Use the arrow buttons and the stop button of the hand-held transmitter to
control sun shading products. Slat products operate based on the radio time
logic (a more detailed explanation of the function principle of the radio time
logic can be found in the instructions on the hand-held transmitter).
The the hand-held transmitter is assigned to a scene, the scene can be
opened by pressing the
C
button.
Gxternal pushbutton
device
When external push button devices are connected to the control, the product
can be operated with these push buttons, independent of the view in the con-
trol display.
When a comfort function has triggered a move command, counter-control or
stopping is possible.
When a safety function has been triggered, neither counter-controlling nor
stopping is possible.
NOTE
The function of the external push button devices is parameterisable; it can be
parameterized in such a way that it differs from the operation on the control
panel or is more restricted.
Manual operation