Faults are indicated by the "Fault" LED (24). In addition the error number is shown in the
display (27). If a fault occurs, the high voltage is switched off immediately. The user can
only continue to work once the fault has been remedied and acknowledged with push
button "Service" (25).
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03505
24
27
25
Code
display Malfunction
Cause
Remedy
E11
Ground monitoring
– Grounding cable is interrupted.
– Check/replace gun cable.
– Gun is not connected.
– Check/replace gun.
– Connect gun.
E12
No coil current/cascade
interrupt
– The cascade is not connected.
– Connect the cascade.
– Cascade is interrupted
– Check/replace cascade.
defective
E13
Coil current too big
– The cascade is defective.
– Check/replace cascade.
E21-E25 Exception error
– Hardware defect has occurred.
– If problem persists, contact the
WAGNER Service Department.
E30
Door switch
– Door open.
– Close door.
– Door switch defective.
– Check/replace door switch.
E40-E43 Gun communication
faulty
– Gun cable defective.
– Check/replace gun cable.
– Operating unit of spray gun
defective.
– WAGNER Service Department.
– Control unit defective.
– WAGNER Service Department.
E60
Password error
– Password not set.
– Password to be set by Service
Center.