7.3
EMERGENCY DEACTIVATION
In the case of unforeseen occurrences, proceed as follows:
1. Close main tap (1).
2. Switch off control unit (2) at main switch (3).
3. Open cabinet door (4) (pull hard).
4. Relieve product pressure by opening ball valve (5).
5
5
B_06775
2
1
3
4
ZIP52 / TOPFINISH DD10 with
product pressure regulator