67
OPERATING MANUAL
VERSION 02/2018
ORDER NUMBER DOC 2366717
7.5.2 ACCESS TO THE DEVICE CONFIGURATION MODE
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03381
3
4
Procedure
1. Switch device to "Standby" by
pressing the "Standby" key (3).
The "Standby" LED (4) lights up
yellow.
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03507
2
25
27
2. Press and hold the "Service" push
button (25).
3. Turn the universal control dial (2)
with the other hand until the LED
display (27) shows the number "10".
Then release the "Service" button (25).
The running text "configuration" is
displayed in the LED display (27).
The device is now in configuration
mode.
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03508
27
6
8
4
4. The first configuration parameter C11
is now displayed in the LED display (27).
The two LED displays "Spray current"
(6) and "High voltage" (8) flash at the
same time.
The "Standby" (4) LED display flashes
quickly.
Note:
The C11 parameter can be changed,
but this will not have any effect.