![WAGNER AquaCoat 5010 GM 5020EAW Operating Manual Download Page 65](http://html1.mh-extra.com/html/wagner/aquacoat-5010-gm-5020eaw/aquacoat-5010-gm-5020eaw_operating-manual_3231225065.webp)
65
OPERATING MANUAL
VERSION 02/2018
ORDER NUMBER DOC 2366717
Review counter status since last service carried out on gun
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03384
2
5
6
17
18
25
26
27
22
Procedure
1. Press the "Service" button (25) to
access the service menu. LED (26)
lights up.
2. Actuate the push button R2 (17) for a
short time; the LED (18) display lights
up.
3. Read off display in the LED display
(27). In the example, 46 hours have
passed since realization of the last
spray gun service. The bar display to
the left (22) indicates that 50% of the
set interval time has passed.
4. By keeping push button (5) pressed
down, the display in the LED display
(27) can be set to "0" (reset after
expiry of the set interval limit).
7.4.13.2 "CARRY OUT SERVICE" DISPLAY
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03385
25
26
Prerequisite
The "Service interval limit" function is
activated (see Chapter
).
"Service spray gun"
Once the time for the defined maintenance
interval has expired, the LED display (26)
starts to flash.
The flashing service display merely acts
as a warning. You can continue working
without any limitations.