36
OPERATING MANUAL
VERSION 02/2018
ORDER NUMBER DOC 2366717
5.6.1.2 CONNECTIONS ON THE REAR SIDE
Pumpe
Pump
Netzeingang
Main power
Lufteingang
Air inlet
Erdungs-Zylinder
Grounding cylinder
Prim. 1AT
Mat. Druckregler
Mat. pressure reg.
Zerstäuberluft
Atomizing air
Pistole
Gun
Türschalter
Door switch
Service
Typ / Type:
VM 5020W
115 - 230VAC
50Hz / 60Hz
2360060
max. 40W
Wagner International A
G
Industriestrasse 22
CH - 9450 Altstätten
Made in Switzerland
Serie Nr.:
Serial No.:
Spannung:
Voltage:
Artikel Nr.:
Article No.:
Eingangsleistung:
Line Power:
Schutzklasse:
Protection Class:
Norm:
Standard:
EN 50059
IP 40
Spannung:
Voltage:
Strom:
Current:
max. 20Vpp
max. 1,0A
Baujahr:
Year of manufacture:
B_05891
28 29
30
31
32
33
34 35 36
37
38
28 Mains input terminal
Connection for mains cable with safety clip.
29 Primary fuse
1.0 Ampere slow-acting.
30 Gun connection
To connect a spray gun.
31 Door switch connection
Connection for the door switch cable.
32 Cover of the service connection
For WAGNER service personnel only!
33 Connection pump air
Hose connector 10 mm; 0.39 inches.
34 Product pressure regulator connection
Hose connector 8 mm; 0.32 inches.
35 Grounding switch air connection
Hose connector 6 mm; 0.24 inches.
36 Atomizing air connection
Hose connector 8 mm; 0.32 inches.
37 Compressed air Inlet
Hose connector 10 mm; 0.39 inches.
38 Grounding (self-locking nut)
Connection for the grounding cable (signal ground).