Secure cables and hoses
B_05954
9. Secure al cables and hoses with cable ties in the AquaCoat cabinet.
The door switch moves up and down on the RH cabinet wall. It must
be ensured that no cables and hoses are located within the travel
of the door switch.
Spray gun
10. Mount product hose, air hose and gun cable to spray gun.
B_05983
2
SW19
2.5 Nm
SW19
SW19
2.5 Nm
Air hose
When screwing on the air hose, a
second open-ended/ring spanner
must be used for bracing.
Gun cable
Order No.
Description
2 *
9992698
Vaseline white, PHHV II
* Use Vaseline sparingly
Control unit
11. Carefully push the VM 5020W control unit back again to the limit stop. Note the
connecting lines and connecting cables at the back of the control unit!
12. Screw the VM 5020W control unit on the cabinet.
Additional Accessories (option)