7.5
DEVICE CONFIGURATION
7.5.1 OVERVIEW OF PARAMETERS
Parameter
Value
Description
C12 External set value
specification
off
The target values for high voltage in kV
and current limitation in µA are adjusted at
the front control panel of the control unit.
(factory setting)
on
- The set values for high voltage in kV and
current limitation in µA are predefined
using the interface's two analog
power inputs. Application example: Set
value specification by a superordinate
controller (PLC).
- Set values can no longer be adjusted at
the front control panel. All recipe functions
(save, call up recipe, etc.) are locked.
C13 Lock
off
Lock is deactivated.
(factory setting)
on
Operating inhibit is activated.
- You can select recipes and control
functions.
- The set values (kV and µA) cannot be
adjusted.
pro
Lock pro (program).
- You can select recipes and control
functions.
- The target values (kV and µA) can be
adjusted but cannot be saved in the
recipes.
C19 Reset recipes
no
No reaction
(factory setting)
res
All programs are set to delivery condition,
if "res" is saved with the "Service" button.
C20 Reset
configuration
no
No reaction
(factory setting)
res
All configuration parameters are set to
delivery condition (factory setting), if "res"
is saved with the "Service" button.