7.4.10 SETTING THE CURRENT LIMITATION
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03377
5
6
Procedure
1. Press the "Current limitation"
button (5) to adjust the limitation of
the spray current.
The LED (6) indicates that current
limitation is selected.
AquaCoat
100
80
60
40
20
µA
80
60
40
20
10
kV
R3
R2
R1
POWER
0
1
POWER
B_03378
22
2
27
2. The current limitation can now be
adjusted using the universal rotary
controller (2) between 10-100 µA
with a resolution of 1 µA.
The corresponding value is indicated
in the LED display (27).
Above the "Current limitation" button (5) is the "Current limitation" bar graph display (22).
If the control unit is in the ready position, this light strip shows the set value as a dot.
The current limitation is an adjustable threshold. If this threshold is exceeded, for example,
by the spray gun having approached the object being sprayed, the high voltage is adjusted
downwards until the threshold is no longer exceeded.
The set values for the target high voltage (40 kV) and for spray current limitation (83 µA)
that are shown in the examples are saved in R2 by pressing and holding (for > 2 seconds)
the receipt push button.