SE RvICINg A ND INSPEC TION
181
W L 30
Cleaning the cooling system
Clean the dirty radiator with compressed air (Fig. 81). You
can also clean heavily contaminated radiators with water
under high pressure.
Clean
•
the engine‘s radiator
• the hydraulic fluid cooler
•
the alternator (with compressed air only!)
ENVIRONMENTAL NOTE
Avoid environmental damage
Clean the loader only in a suitable place where the
waste water can be collected in an ecologically
sound manner.
Collect contaminated waste water and dispose of
it in an ecologically sound manner.
The greater the amount of dust in the air, the
more frequently the radiator has to be checked
and cleaned.
Always cover up the suction connection of the air
filter before cleaning the radiator.
Do not damage the radiator fins when cleaning
the radiator. Straighten any twisted radiator fins
carefully.
Fig. 81