SE RvICINg A ND INSPEC TION
133
W L 30
Residual pressure in the hydraulic system
Personal injury hazard.
• Pressurized jets of fluid can penetrate human skin.
•
In the event that oil penetrates the skin, seek immediate medical attention to reduce the risk of infection and
complications from infection.
• Confirm that the hydraulic system pressure has been relieved before attempting to repair the system or
component.
•
Even for a loader parked on a horizontal surface with its loader lift arms completely lowered and engine turned
off, there can still be considerable residual pressure in parts of the hydraulic system.
• Residual pressure reduces gradually at first. If a hydraulic system is to be opened immediately after being
shut down, the system shall be relieved before repairs are attempted. Do not attempt to work on the system
if the components are not comfortable to touch. Hot surfaces and liquids can cause severe burns.
• For loaders with load holding control devices on the lifting and/or tipping cylinder, you must open the valves
as described in Section 8, page 126 »Relieving residual pressure in the hydraulic system« in order to lower
the loader lift arms.
Summary of Contents for WL 30
Page 1: ...www wackerneuson com Operator s Manual Wheel Loader WL 30...
Page 2: ...December 10 Edition...
Page 17: ...BASIC INFORMATION 15 WL30...
Page 48: ...TECHNICAL DATA 46 3 4 Dimensions Fig 11 Dimensions...
Page 61: ...Description of the indicator warning and control elements 59 WL30...
Page 126: ...Towing and transporting 124 Fig 58 Tying down the loader...
Page 161: ...SERVICING AND INSPECTION 159 WL30 2 1 Fig 63 Cab tilt lever...
Page 235: ...Appendix 233 WL30 For personal notes...
Page 245: ...List of figures 243 WL30...