Maintenance
HI 110 / 200 / 300
56
ghi_tx001450gb.fm
7.7
Inspecting the Flame Head
Requirements
Machine shut down and cool to the touch
Machine properly positioned
When
Inspect the flame head prior to the first seasonal use, during regular maintenance,
and as needed.
Procedure
To inspect the flame head
(a)
, carry out the following procedure.
1. Remove the access panel. See topic
Removing the Access Panel
.
2. Remove the burner assembly. See topic
Removing and Installing the Burner
Assembly.
The flame head is attached.
3. Inspect the flame head for the following:
Wear. Replace if necessary.
Cleanliness. Clean the flame head if necessary.
Thermal stress. Replace if necessary.
4. Re-install the burner assembly. See topic
Removing and Installing the Burner
Assembly.
CAUTION
Hot surface hazard. The machine surfaces may be hot.
f
Allow the machine to cool for a minimum of ten minutes before touching it.
ghi_gr007382
a
a