HI 110 / 200 / 300
Maintenance
ghi_tx001450gb.fm
55
3. Inspect and, if necessary, clean the motor
(m)
using compressed air.
4. Clean the fan blades using a stiff brush.
5. Reinstall the internal access panel.
6. Reinstall the fan guard.
7.6
Cleaning the Interior Shell
Prerequisites
Machine shut down and cool to the touch
Power source disconnected
When
Clean the interior shell prior to the first seasonal use, every 1200 hours or annually,
or as needed.
To clean the interior shell, carry out the following procedure.
1. Remove the fan guard
.
See topic
Cleaning the Fan Blades and Motor.
2. Remove the internal access panel. See topic
Removing the Internal Access Panel
.
3. Inspect and clean the interior shell using compressed air.
4. Re-install the internal access panel.
5. Re-install the fan guard.
CAUTION
Hot surface hazard. The machine surfaces may be hot.
f
Allow the machine to cool for a minimum of ten minutes before touching it.
ghi_gr007381