HI 110 / 200 / 300
Burner Setup
ghi_tx001449gb.fm
41
6.2
Removing and Installing the Burner Assembly
Requirements
Machine shut down and cooled
Machine properly positioned
Procedure
Before performing any maintenance on the burner assembly, it must be removed
from the machine. To remove or install the burner assembly perform the following
procedure.
Removal
1. Shut down the machine and allow it to cool.
2. Disconnect the power cord from the power source.
3. Remove the access panel. See topic
Removing the Access Panel
.
4. Remove the screw
(d)
to disconnect the ground wire
(c)
from the burner
assembly
(b)
.
5. Rotate the burner assembly
counter-clockwise and remove it from the flame
head and air tube assembly
(e).
6. Perform the required maintenance.
Note:
Refer to the maintenance procedures in this manual.
7. Reinstall the burner assembly. Refer to the steps below to install the burner
assembly.
Installation
1. Place the burner assembly into the flame head and air tube assembly
.
2. Rotate the burner assembly clockwise to lock it into place.
3. Install the ground wire using the screw
(d).
4. Reinstall the access panel.
CAUTION
Hot surface hazard. The machine surfaces may be hot.
f
Allow the machine to cool for a minimum of ten minutes before touching it.
d
b
e
c
wc_gr007378