HI 110 / 200 / 300
Operation
ghi_tx001447gb.fm
33
4.12
Pre-Starting Checks
Requirements
Machine properly positioned
Power connected to the machine
Checks
Before starting the machine, check the following items:
Result
The machine is ready to turn on.
Item
Task
Fuel sight gauge (if equipped)
Check that the fuel tank is full (if applicable).
Fuel tank cap
Check that the fuel tank cap (if applicable) is
secure.
Operation mode switch
Check that the operation mode switch is in the
OFF position.
Main control panel
Check that proper power supplies have been con-
nected at the main control panel. See topic
Connecting Power to the Machine
.
Remote thermostat (if installed)
Check that the remote thermostat has been cor-
rectly installed. See topic
Installing the Remote
Thermostat or Thermostat Receptacle Plug.
Ducts and duct adapters
Check that all ducts and duct adapters have been
properly installed. See topic
Installing the Heater
Duct.