2 - 14
INSTALLATION
JUNE 2021
32DSKF02.D
TITANIUM S-SERIES AND K-SERIES
PUBLIC USE SERVICE MANUAL
RSM0003600
A P P L Y 5 0 LB . L O A D
N O T E : H A N D R A IL S N O T S H O W N
F O R C L A R IT Y .
KNUCKLE L IN K
FIGURE 2-24: PRESSURE SWITCH TEST AT FLOOR LEVEL
NOTE:
Weight must be 50 lbs. and placed 6 inches from rear edge of platform mesh as shown in
Figure 2-25
.
FIGURE 2-25: 50 LB. WEIGHT PLACEMENT ON PLATFORM
b.
Place a 6” x 6” x 12”, 50 lb. load on the rear, center portion of platform then raise platform to floor level by
pressing and holding the STOW switch.
c.
Refer
to
Figure 2-26
. If an alternate weight is to be used, the center of the weight must be 6 inches from
the rear edge of the platform mesh.
FIGURE 2-26: ALTERNATE 50 LB. WEIGHT