3 - 7
MAINTENANCE
JUNE 2021
32DSKF02.D
TITANIUM S-SERIES AND K-SERIES
PUBLIC USE SERVICE MANUAL
RSM0051400
1
2
SWITCH ASSY FOR RH PUMP SHOWN
FIGURE 3-7: PUSH AND HOLD UP
f.
Refer
to
Figure 3-6.
When the platform is at floor level, observe where the bridgeplate sits on the bridge-
plate switch sensor assembly.
g. Refer
to
Figure 3-7.
Slowly turn the UP CUTOFF ADJUSTMENT SCREW
counterclockwise
to adjust the
bridgeplate backward or
clockwise
to adjust the bridgeplate forward.
h. Cycle platform to DEPLOY then UP to floor level. Observe the position of the bridgeplate to the bridgeplate
switch sensor assembly and make any necessary adjustments. The bridgeplate should sit on the bridge-
plate switch sensor, as shown in
Figure 3-6
.
6.
STOW-LOCK
ADJUSTMENT
NOTE:
The purpose of this procedure is to replace and properly set the stow lock.
a. Fully
STOW
platform.
b. Refer
to
Figures 3-8.
Use a 3/16” allen wrench to remove the two screws and washers that attach the
base latch block to the bridgeplate. Partially deploy platform then remove base latch block for replacement.
RSM0051500
BASE LATCH
SCREW (2X)
WASHER (2X)
BASEPLATE
PLATFORM RELEASE
LATCH
BRIDGEPLATE
FIGURE 3-8: BASE LATCH
c. Place sharp edge of the base latch block against the blade of the platform latch release weldment in the
baseplate, as shown in
Figure 3-8
.
d. Stow the platform.
e. Add medium strength thread lock to the screws then install the two screws and washers. Turn the screws
out one turn so that the screws are not completely tightened.
NOTE:
This is done to ensure the sharp edge of the base latch block contacts the blade of the platform latch
release weldment in the baseplate before tightening.