3 - 5
MAINTENANCE
JUNE 2021
32DSKF02.D
TITANIUM S-SERIES AND K-SERIES
PUBLIC USE SERVICE MANUAL
RSM0051100
IRS PULLEY
MOUNT BLOCK
VERTICAL ARM
GROOVED
BEARING
IRS ACTUATOR
CAM ASSEMBLY
IRS CABLE ASSEMBLY
2
3
4
5
6
7
1
FIGURE 3-3: BRIDGEPLATE CABLE ROUTING
4.
S-SERIES AND K-SERIES LIMIT SWITCH STATES
Refer to
Figure 3-4
. The limit switch actuation diagram shows the state of all limit switches as the platform travels
from fully stowed, to vehicle floor level, and to ground level. The solid (
▬
) line indicates the normally CLOSED por-
tion of switch is operational, while the two thin lines (
═
) indicate the normally OPEN portion of the switch is opera-
tional. The dotted lines (
∎ ∎ ∎
) are used to show switch states beyond normal travel boundaries of the platform.
This is useful to show the operation of switches that change state at folded or ground level positions. For proper
operation of lift, the switch actuations must overlap as shown.
RSM0005400
FIGURE 3-4: LIMIT SWITCH ACTUATION CHART