3.3. Ratings
A. Voltage
• 600 Volt Max. DC or Peak AC, use of wire M22759/11
B. Temperature
• -40°C to 125°C
3.4. Performance and Test Description Product is designed to meet electrical, mechanical, and
environmental requirements specified in Table 3 1. Unless otherwise specified, all tests should
be performed at free air, room temperature, and ambient environmental conditions.
3.5. Test Requirements and Procedures Summary
Product Performance Specifications
Category
Test Description
Requirement
Procedure
Preliminary
Examination of Product
Meets requirements of product
drawing
1
Visual, dimensional, and
functional examination per
applicable quality inspection
plan
Electrical
Contact Resistance
30 mΩ
EIA-364-06
Insulation Resistance
1000 MΩ minimum
EIA-364-21: Test between
adjacent contacts assembled in
housing at 500VDC
Dielectric Withstanding Voltage
1050 VDC test voltage at sea
level
EIA-364-20: Test between
adjacent contacts at 0.5 mA
Cross Talk
-30dB to 6.25 GHz
-40dB to 6.25 GHz
Cross talk between adjacent
differential pair within the same
insert
Cross talk between differential
pair in adjacent inserts
Impedance
100Ω ±10Ω Per Differential Pair
Insertion Loss
-1dB to 6.25 GHz
Mechanical
Durability
See test sequence: Table 3-2
EIA-364-09: Mate and un-mate
sample for 10,000 cycles
Retention Force: Receiver
Contact
Contact shall not dislodge from
module
EIA-364-29: Apply axial load of 5
lbs to contact
Retention Force: ITA Contact
Insertion Force: Receiver
Contact
Force to insert contacts into
module ≤ 1.5 lbf
EIA-364-05
Insertion Force: ITA Contact
Mating Force
0.75 lbf Max per insert
EIA-364-13: Measure force
necessary to mate samples at a
normal rate of engagement of
the ITA
Un-mating Force
≤ 1 lbf per insert
EIA-364-13: Measure force
necessary to un-mate samples at
a normal rate of disengagement
of the ITA
1
Shall meet visual requirement, show no physical damage and shall meet requirement of additional tests as specified in Test
Sequence in Table 3.2.
Table 3.1: Test requirements and procedure summary.