112
The tap must be closed when
connecting up to external air supply.
Open it slowly when checking
pressure drop.
From external air supply
Connection, pressure-
drop indicator
Free air release
6831
Pressure-drop indicator
Checking
The pressure-drop indicator should show full red at
the Vp vacuum value given in the Specifications. If
the indicator is not faulty, depress the reset button.
If faulty, replace the pressure-drop indicator.
When fitting the pressure-drop indicator, make
sure it is screwed on tight. There must not be any
air leakage on the “clean” side of the air cleaner.
Intercooler
All the DH10A-engines have the single-circuit type in-
tercooler with a separate cooling circuit, radiator and
pump.
The intercooler lowers the temperature of the inlet air
and this has a better effect on engine power. The sys-
tem cools the inlet air down to approx. 60
°
C. Concern-
ing pressure testing and description of the coolant cir-
cuits, refer to “Cooling system”.