14
Thermostats
Type ..........................................
Gear-driven pump
with two pump
gears
Coolant pump
Impeller press-in depth
Fans B10M
Hydraulic-driven cooling fan
Pump, type/designation ............
Vickers PVE 19 R
Fan motor, type/designation .....
Volvo Flygmotor
F11-19
Fan speed
at engine speed 1000 r/min
and coolant temperature
under 90
°
C .......................
approx. 700 r/min
above 94
°
C ......................
approx. 2000 r/min
Filter, part no. ...........................
4823936
Drive belts ................................
HC 50 1150 Lw x 2
P/N 966846
Fans B10B
Temperature-controlled cooling fan
Type ...............................
Bimetal plate/
coolant coupling
Fan speed at engine speed
38.3 r/s (2300 r/min),
under +37
°
C .............
min. 7 r/s (420 r/min)
above +63
°
C .............
min. 35.7 r/s (2100 r/min)
Temperatures refer to temp. round bimetal plate.
Drive-belt driven cooling fan
Fan drive reduction ...................
1:1.22
Belt type/size (4 belts included
in this drive) ..........................
HC 12.5 x 1550
P/N 9515805
Engine circuit (1)
Type ..........................................
Piston thermostat
Number .....................................
2
Marking ....................................
82
Opening temperature ................
82
±
2
°
C
Fully open at .............................
95
±
2
°
C
Heating distributor thermostat (2)
Marking ....................................
60
Opening temperature ................
58–62
°
C
Fully open at .............................
approx. 77
°
C