CONDEXA PRO
60
ON
OFF
3
2
1
The
Vokera CONDEXA PRO
Boiler is supplied for ope-
ration on G20 (natural gas). However, it can be conver-
ted for operation on G30-G31 (LPG), using the special
kit supplied.
Before performing the conversion:
- Disconnect the power supply from the appliance by
moving the main switch to "off";
- Close the fuel valve.
To install the kit:
- Unscrew the fastening screws (1) on the front panel (2)
- Pull the base of the panel (2) outwards and then
upwards to release it from the frame and then remove
it
- Set parameter 36 to 3 or 4, according to the length (L)
of the flue:
3 = L < 15 m
4 = L > 15 m.
The fan speed is controlled automatically.
- Disassemble the gas valve from the fan assembly by
loosening the three screws (3)
b
The conversion must only be carried out by
Vokera
Ltd
or personnel authorised by
Vokera
, even when
the boiler is already installed.
b
Once the conversion has been completed, set the
boiler again as described in the paragraph on
"Adjustments".
CONVERSION FROM ONE TYPE OF GAS TO THE OTHER