HB130E - SM - Rev. 07/44
... continue technical data 332-5HDx0
Temperature error
(with reference to the output range)
±0.01%/K
Linearity error
(with reference to the input range)
±0.15%
Repeatability
(in steady state at 25°C,
referred to output range)
±0.05%
Output ripple;
range 0 to 50kHz
(referred to output range)
±0.05%
Status, Interrupt, Diagnostics
Interrupts
- Diagnostic interrupt
parameterizable
Diagnostic functions
parameterizable
- Power supply
LED (green)
- Diagnostic information readable
possible
Substitute value can be applied
yes
Data for selecting an actuator
Output range (rated values)
-
Voltage
-
0...10V
- Current
4 ... 20mA
-
Load resistance (in the nominal range of the output)
- for voltage outputs
-
min. 1k
Ω
capacitive load
-
max. 1µF
- for current outputs
max. 500
Ω
-
inductive load
max. 10mH
-
Voltage outputs
- Short-circuit protection
-
yes
- Short-circuit current
-
25mA
Current outputs
- No-load voltage
15V
-
Destruction limit against voltage/currents applied from outside
- Voltage at outputs to M
ANA
max. 15V
- Current
max. 25mA
max. 30mA
Connecting actuators
- for voltage output
2-conductor connection
-
possible
- for current output
2-conductor connection
possible
-
Summary of Contents for HB130E SM
Page 1: ...Manual VIPA System 300V SM Order no VIPA HB130E_SM Rev 07 44...
Page 2: ...Lerrzeichen...
Page 6: ...Contents Manual VIPA System 300V ii HB130E SM Rev 07 44...
Page 14: ...Chapter 1 Basics Manual VIPA System 300V 1 6 HB130E SM Rev 07 44...
Page 58: ...Chapter 4 Digital Output Modules Manual VIPA System 300V 4 24 HB130E SM Rev 07 44...
Page 128: ...Index Manual VIPA System 300V A 2 HB130E SM Rev 07 44 M Stich...