Coding in the delivered condition
Possible change
82:0
Operation with natural
gas
82:1
Operation with LPG
83:15
Ignition start gas vo-
lume 15%
83:0
to
83:31
Start gas volume adjusta-
ble from 0 to 31%
84:0
Start capacity correc-
tion 0%
84:
–
8
to
84:7
Start capacity correction
adjustable from -16 to
+14%.
One step equals 2%.
85:0
Standard mode
85:1
Manual calibration of the
combustion control unit.
The red fault indicator
also flashes during cali-
bration. The process has
terminated when the red
lamp no longer flashes
(after approx. 1 min). The
air factor can then be
manually altered in cod-
ing address 7d.
Note
Heat must be drawn off
during manual calibra-
tion.
Repairs
(cont.)
92
Troubleshooting
5692
569
GB