A
Consecutive number in the user
list
B
User number
1.
Press
L
and
d
simultaneously
for approx. 2 s. The user check has
been initiated.
2.
Select the required user with
a
and
b
.
3.
Activate a check with
d
.
"
Check
" flashes until its comple-
tion. The display and all key illumi-
nations for the selected user flash
for approx. 60 s.
&
"
Check OK
" flashes during com-
munication between both
devices.
&
"
Check not OK
" flashes if there
is no communication between
both devices. Check the LON
connection.
4.
For checking further users, proceed
as described under items 2 and 3.
5.
Press
L
and
d
simultaneously
for approx. 1 s. The user check is
completed.
Adjusting the heating curve (only for weather-compensated
control units)
The heating curves illustrate the rela-
tionship between the outside tem-
perature and the boiler water or the
flow temperature.
To put it simply: The lower the outside
temperature, the higher the boiler
water or flow temperature.
The room temperature, again,
depends on the boiler water or the
flow temperature.
Settings in the delivered condition:
&
Slope = 1.4
&
Level = 0
Further details regarding the individual steps
(cont.)
33
Initial start-up, inspection, maintenance
5692
569
GB
Summary of Contents for Vitodens 300
Page 111: ...Parts lists cont 111 Parts lists 5692 569 GB...
Page 112: ...Parts lists cont 112 Parts lists 5692 569 GB...
Page 113: ...Parts lists cont 113 Parts lists 5692 569 GB...
Page 114: ...Parts lists cont 114 Parts lists 5692 569 GB...
Page 115: ...Parts lists cont 115 Parts lists 5692 569 GB...
Page 127: ...127 5692 569 GB...