Coding in the delivered condition
Possible change
67:40
In conjunction with the
Vitosolic solar control
unit: Set DHW value 3
67:0
to
67:60
DHW set value adjusta-
ble from 0 to 60 °C
6C:100
Set speed; internal cy-
linder primary pump
100%
6C:0
to
6C:100
Set speed adjustable
from 0 to 100%
6F:100
Maximum output for
DHW heating 100%, de-
faulted by the boiler
coding card
6F:0
to
6F:100
Max. output during DHW
heating adjustable from 0
to 100%
71:0
*
1
DHW circulation
pump: ON according to
DHW time program ON
(Vitotrol 300 enables
separate switching
times)
71:1
OFF during DHW heating
to set value 1
71:2
ON during DHW heating
to set value 1
72:0
*
1
DHW circulation
pump: ON according to
DHW time program
72:1
OFF during DHW heating
to set value 2
72:2
ON during DHW heating
to set value 2
73:0
*
1
DHW circulation
pump: ON according to
DHW time program
73:1
to
73:6
During the time program
1x/h ON for 5 min
up to 6x/h ON for 5 min
73:7
Constantly ON
General
76:0
Without LON communi-
cation module
76:1
With LON communication
module; automatic recog-
nition
77 :1
LON user number
77 :2
to
77 :99
LON user number, adjus-
table from 1 to 99:
1-4 = boiler
5 = cascade
10 - ... = Vitotronic 050
99 = Vitocom
Note
Allocate each number
only
once.
79:1
*
1
Control unit is fault
manager
79:0
Control unit is not fault
manager
Code 2
(cont.)
49
Coding
5692
569
GB
*1
Only for weather-compensated control units.
Summary of Contents for Vitodens 300
Page 111: ...Parts lists cont 111 Parts lists 5692 569 GB...
Page 112: ...Parts lists cont 112 Parts lists 5692 569 GB...
Page 113: ...Parts lists cont 113 Parts lists 5692 569 GB...
Page 114: ...Parts lists cont 114 Parts lists 5692 569 GB...
Page 115: ...Parts lists cont 115 Parts lists 5692 569 GB...
Page 127: ...127 5692 569 GB...