Inspection and cleaning aperture
E
Drain
HR
Heating water return
HV
Heating water flow
KW
Cold water
SPR Sensor well for cylinder temperature sensor (internal diameter
7 mm)
WW DHW
Z
DHW circulation
Cylinder capacity
l
160
200
a
mm
581
581
b
mm
605
605
c
mm
1189
1409
d
mm
1055
1275
e
mm
843
885
f
mm
635
635
g
mm
335
335
h
mm
70
70
i
mm
317
317
Pressure drop on the DHW side
See the separate datasheet for the Vitocell 300-V.
DHW output data at rated heating output
Rated heating output for DHW heating
kW
17.3
22.7
29.1
Continuous DHW output
for DHW heating from 10 to 45 °C and an average boiler water
temperature of 70 °C
Cylinder capacity 160 l
kW
17.3
22.7
26
l/h
425
555
630
Cylinder capacity 200 l
kW
17.3
22.7
28
l/h
425
555
680
Performance factor N
L
to DIN 4708
Cylinder capacity 160 l
1.7
1.7
1.7
Cylinder capacity 200 l
2.9
2.9
2.9
Peak output
over 10 minutes
Cylinder capacity 160 l
l/10 min
177
177
177
Cylinder capacity 200 l
l/10 min
226
226
226
Delivered condition
Vitocell 300-W, type EVIA-A+/EVIA-A
160 to 200 l capacity
DHW cylinder made from stainless steel.
■ Integral welded sensor well for cylinder temperature sensor/
temperature controller (internal diameter 17 mm)
■ Thermometer
Separate DHW cylinders for Vitodens 200-W