Gas boiler, type B and C, category II
2N3P
Type
B2TE
Rated heating output range (details to EN 15502)
T
F
/T
R
= 50/30 °C
Natural gas
kW
1.9 - 19.0
1.9 - 25.0
1.9 - 32.0
LPG
kW
2.5 - 19.0
2.5 - 25.0
2.5 - 32.0
T
F
/T
R
= 80/60 °C
Natural gas
kW
1.7 - 17.4
1.7 - 22.9
1.7 - 29.3
LPG
kW
2.2 - 17.4
2.2 - 22.9
2.2 - 29.3
DHW loading cylinder
Capacity
l
100
100
100
Permiss. operating pressure (DHW side)
bar
10
10
10
MPa
1
1
1
Continuous DHW output
kW
19.74
26.53
32.50
For DHW heating from 10 to 45 °C
l/h
484.80
648.80
793.80
Performance factor N
L
*10
1.4
2.1
2.6
Initial DHW output
For DHW heating from 10 to 45 °C
l/10 min
163.70
196.20
215.50
Supply values
Relative to the max. load and 1013 mbar/15 °C
Natural gas E
m
3
/h
2.40
3.12
3.69
Natural gas LL
m
3
/h
2.79
3.63
4.29
LPG
kg/h
1.76
2.29
2.71
Flue gas parameters
Temperature (at a return temperature of 30 °C)
– At rated heating output
°C
41
46
59
– At partial load
°C
38
38
38
Temperature (at a return temperature of 60 °C)
°C
67
72
77
Mass flow rate (for DHW heating)
Natural gas
– At rated heating output
kg/h
40.4
54.2
62.1
– At partial load
kg/h
3.2
3.2
3.2
LPG
– At rated heating output
kg/h
39.8
53.2
61.1
– At partial load
kg/h
3.9
3.9
3.9
Available draught
Pa
250
250
250
mbar
2.5
2.5
2.5
Max. amount of condensate
To DWA-A 251
l/h
3.2
4.1
4.9
Condensate connection
(hose nozzle)
Ø mm
20 - 24
20 - 24
20 - 24
Flue gas connection
Ø mm
60
60
60
Ventilation air connection
Ø mm
100
100
100
Standard seasonal efficiency [to DIN] at
T
F
/T
R
= 40/30 °C
%
Up to 98 (H
s
) [gross cv]
Energy efficiency class
– Heating
A
A
A
– DHW heating, draw-off profile XL
A
A
A
*10
At 70 ºC average boiler water temperature and cylinder storage temperature Tcyl = 60 ºC.
DHW performance factor NL depends on cylinder storage temperature Tcyl.
Standard values: Tcyl = 60 ºC → 1.0 × NL Tcyl = 55 ºC → 0.75 × NL Tcyl = 50 ºC → 0.55 × NL Tcyl = 45 ºC → 0.3 × NL.
Vitodens 222-F, type B2TE
(cont.)
VITODENS
VIESMANN
35
5853906
4
Summary of Contents for Vitodens 200-W B2HE
Page 154: ...154 VIESMANN VITODENS...
Page 155: ...VITODENS VIESMANN 155 5853906...