6.1 Vitocell 100-W below the boiler (type CUGA and CUGA-A), made from steel, with
Ceraprotect enamel coating
■ Installed below the boiler
■ With internal indirect coil, made from steel, with Ceraprotect enamel coating
Specification
Type
CUG
CUGA
CUGA-A
CUGA
CUGA-A
Cylinder capacity
l
100
120
150
Heating water capacity
l
6
6.5
6.5
Gross volume
l
106
126.5
156.5
DIN registration no.
9W245/11-13 MC/E
Connections
(male thread)
Heating water flow and return
R
1
1
1
1
1
DHW and cold water
R
¾
¾
¾
¾
¾
DHW circulation
R
¾
¾
¾
¾
¾
Permiss. operating pressure
Heating water and DHW sides
bar
10
10
10
10
10
MPa
1
1
1
1
1
Permissible temperatures
– Heating water side
°C
160
160
160
160
160
– DHW side
°C
95
95
95
95
95
Standby heat loss
kWh/24 h
1.49
1.10
0.75
1.21
0.84
Dimensions
Length a
mm
574
596
596
641
641
Width b
7
mm
553
596
596
641
641
Height c
mm
836
914
914
942
942
Weight
kg
51
75
75
88
88
Heating surface
m
2
0.9
1.0
1.0
1.0
1.0
Energy efficiency class
C
B
A
B
A
Vitocell 100-W, type CUG, 100 l
g
b
a
f e
d
c
HR
HV
WW
Z
KW
TH
HR
Heating return
HV
Heating flow
KW Cold water (drain)
WW DHW
TH
Sensor well for cylinder temperature sensor (internal diameter
7 mm)
Z
DHW circulation
Dimensions
Dimension
a
mm
574
b
mm
553
c
mm
836
d
mm
700
e
mm
399
f
mm
78
g
mm
308
Separate DHW cylinders for Vitodens 200-W