Gas boiler, type B and C, category II
2N3P
Type
B2HE
Rated heating output range (details to EN 15502)
T
F
/T
R
= 50/30 °C
Natural gas
kW
1.9 - 11.0
1.9 - 19.0
1.9 - 25.0
1.9 - 32.0
LPG
kW
2.5 - 11.0
2.5 - 19.0
2.5 - 25.0
2.5 - 32.0
T
F
/T
R
= 80/60 °C
Natural gas
kW
1.7 - 10.1
1.7 - 17.4
1.7 - 22.9
1.7 - 29.3
LPG
kW
2.2 - 10.1
2.2 - 17.4
2.2 - 22.9
2.2 - 29.3
Flue gas parameters
Temperature
(at a return temperature of 30 °C)
– At rated heating output
°C
39
41
46
59
– At partial load
°C
38
38
38
38
Temperature
(at a return temperature of 60 °C, for
DHW heating)
°C
64
65
67
72
Mass flow rate
(for DHW heating)
Natural gas
– At rated heating output
kg/h
31.7
31.7
41.6
54.9
– At partial load
kg/h
3.2
3.2
3.2
3.2
LPG
– At rated heating output
kg/h
30.1
30.1
41.0
53.9
– At partial load
kg/h
3.9
3.9
3.9
3.9
Available draught
*2
Pa
250
250
250
250
mbar
2.5
2.5
2.5
2.5
Max. amount of condensate
To DWA-A 251
l/h
2.5
2.5
3.3
4.2
Condensate connection (hose nozzle)
Ø mm
20 - 24
20 - 24
20 - 24
20 - 24
Flue gas connection
Ø mm
60
60
60
60
Ventilation air connection
Ø mm
100
100
100
100
Standard seasonal efficiency [to DIN] at
T
F
/T
R
= 40/30 °C
%
Up to 98 (H
s
) [gross cv]
Energy efficiency class
A
A
A
A
Gas condensing combi boiler
Gas boiler, type B and C, category II
2N3P
Type
B2KE
Rated heating output range (details to EN 15502)
T
F
/T
R
= 50/30 °C
Natural gas
kW
1.9 - 19.0
1.9 - 25.0
1.9 - 32.0
LPG
kW
2.5 - 19.0
2.5 - 25.0
2.5 - 32.0
T
F
/T
R
= 80/60 °C
Natural gas
kW
1.7 - 17.4
1.7 - 22.9
1.7 - 29.3
LPG
kW
2.2 - 17.4
2.2 - 22.9
2.2 - 29.3
Rated heating output for DHW heating
Natural gas
kW
1.7 - 26.2
1.7 - 30.4
1.7 - 33.5
LPG
kW
2.2 - 26.2
2.2 - 30.4
2.2 - 33.5
Rated heat input
Natural gas
kW
1.8 - 27.3
1.8 - 31.7
1.8 - 34.9
LPG
kW
2.3 - 27.3
2.3 - 31.7
2.3 - 34.9
Product ID
CE-0085CT0017
IP rating
to EN 60529
IP X4
Gas supply pressure
Natural gas
mbar
kPa
20
2
20
2
20
2
LPG
mbar
kPa
50
5
50
5
50
5
Max. permiss. gas supply pressure
*3
Natural gas
mbar
kPa
25.0
2.5
25.0
2.5
25.0
2.5
*2
CH: Available draught 200 Pa; 2.0 mbar
*3
If the gas supply pressure is higher than the maximum permissible value, install a separate gas pressure governor upstream of the sys-
tem.
Vitodens 200-W
(cont.)
VITODENS
VIESMANN
7
5853906
1