24
Total weight with filled DHW cylinder
Type AWT-AC
Weight in kg
241.A04
424
241.A07
424
241.A10
427
241.A13
427
Minimum room volume (to
DIN EN 378):
Type AWT-AC
Minimum room
volume in m
3
241.A04
2.7
241.A07
4.9
241.A10
6.1
241.A13
6.1
Minimum clearances
Note
If using the secondary circuit connection
set (accessories), maintain a wall clear-
ance of approx. 80 mm.
Minimum room height h
Installation
h in mm
■
Without
pre-assembly/
DHW connection set (ac-
cessories)
2250
■
With
pre-assembly/DHW
connection set (accesso-
ries)
2350
Observe engineering informa-
tion.
Vitocal technical guide
Handling
The cylinder module can be removed
during transport.
!
Please note
Avoid damaging the appliance
during handling.
Never
put weight on the top, front
or side panels of the appliance.
Installation sequence
Installing the internal unit
(cont.)
5623 661 GB