17
Required parameter settings
To call up
"Coding level 1"
for setting
the parameters, see the commissioning
assistant on page 83 and page 86.
Parameter
Setting
"System definition"
■
"System scheme 7000"
"6"
DHW heating:
"Time program DHW heating"
Set time program (see op-
erating instructions)
"Time program DHW circulation"
(if a DHW circulation pump is installed)
Set time program (see op-
erating instructions)
"DHW"
■
"Enable booster heaters for DHW heating 6014" "1"
■
"Enable electric heaters for DHW heating 6015"
"1"
"Solar"
■
"Solar control unit type"
"4"
Instantaneous heating water heater
:
"Electr booster heater"
■
"Enable instantaneous heating water heater
7900"
"1"
■
"Enable instant. heating water heater for central
heating 7902"
"0"
■
"Time prog elec heater"
Set time program (see op-
erating instructions)
"Cooling"
■
"Cooling function 7100"
"3"
■
"Cooling circuit 7101"
"2"
Remote controls
(if installed):
"Heating circuit 1"
■
"Remote control 2003"
"1"
"Heating circuit 2"
■
"Remote control 3003"
"1"
Preparing for installation
System example, ID: 4605415_1202_02
(cont.)
5623 661 GB
Installation