139
Type AWT-AC
241.A04
241.A07
241.A10
241.A13
Integral cylinder
Capacity
l
220
220
220
220
Continuous output
when heating DHW
from 10 to 60 °C
l/h
203
254
306
357
Performance factor N
L
to DIN 4708
1.5
1.5
1.6
1.6
Max. draw-off rate at
the stated performance
factor N
L
and DHW
heating from 10 to
45 °C
l/min
16.8
16.8
17.3
17.3
Max. collector area with
orientation to the south
(flat-plate/tube collec-
tors)
m
2
5/3
5/3
5/3
5/3
Max. permissible DHW
temperature
°C
95
95
95
95
Dimensions
External unit
Total length
mm
869
1040
900
900
Total width
mm
290
340
340
340
Total height
mm
610
865
1255
1255
Internal unit
Total length
mm
680
680
680
680
Total width
mm
600
600
600
600
Total height
mm
2075
2075
2075
2075
Total weight
External unit
kg
43
66
110
110
Internal unit
kg
204
204
207
207
Permissible operat-
ing pressure
, secon-
dary side
bar
3
3
3
3
Specification