130
DHW
Parameter
Code
Delivered condi-
tion
Commis-
sioning
"Set DHW temperature"
6000
500 (
≙
50 °C)
"Min. DHW temperature"
6005
100 (
≙
10 °C)
"Max. DHW temperature"
6006
600 (
≙
60 °C)
"Hysteresis DHW temperature heat
pump"
6007
50 (
≙
5 K)
"Hysteresis DHW temperature booster
heater"
6008
100 (
≙
10 K)
"Start optimisation for DHW heating"
6009
0
"Stop optimisation for DHW heating"
600 A 0
"Set DHW temperature 2"
600C
600 (
≙
60 °C)
"Temperature sensor at bottom of
DHW cylinder"
600E
0
"Enable booster heaters for DHW heat-
ing"
6014
0
"Enable electric heaters for DHW heat-
ing"
6015
1
"Priority DHW heating with combi cyl-
inder"
6016
0
"Start attempts for DHW after high
pressure shutdown"
6017
1
"Cylinder primary pump enable"
601F
1
"Operating mode cylinder primary
pump"
6020
3
Solar
Parameter
Code
Delivered condi-
tion
Commis-
sioning
"Type solar control unit"
7A00
0
"Max. collector temperature"
7A01
1300 (
≙
130 °C)
"Start hysteresis solar circuit pump"
7A02
70 (
≙
7 K)
"Stop hysteresis solar circuit pump"
7A03
30 (
≙
3 K)
"Flow rate solar circuit for calculating
solar yield"
7A07
100 l/h
"Display message incorrect circula-
tion"
7A09
1
Commissioning/service reports
Control parameter report
(cont.)
5623 661 GB