90
Cooling function
Cooling function parameters
Setting
"Cooling"
Ó
"Cooling function 7100"
"3"
"Cooling"
Ó
"Cooling circuit 7101"
■
"1"
(heating circuit A1/HC1)
■
"2"
(heating circuit M2/HC2)
■
"4"
(separate cooling circuit
SKK)
Instantaneous heating water heater
Parameters for
Instantaneous heating water heater
Setting
"Electr booster heater"
Ó
"Enable instantaneous heating water heater
7900"
"1"
poss.
"Electr booster heater"
Ó
"Enable instant. heating water heater for cen-
tral heating 7902"
"1"
"Electr booster heater"
Ó
"Output for instant. heating water heater at
power-OFF 790A"
■
"1"
for 3 kW
■
"2"
for 6 kW
■
"3"
for 9 kW
poss.
"DHW"
Ó
"Enable electric heaters for DHW heating
6015"
"1"
Swimming pool water heating
Parameters for swimming pool heating
Setting
"System definition"
Ó
"External extension 7010"
"1"
"System definition"
Ó
"Swimming pool 7008"
"1"
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5623 661 GB