91
Vitovent 300-F
Parameters for Vitovent 300-F
Setting
"Ventilation"
Ó
"Vitovent enable 7D00"
"1"
Other enabling settings, if applicable:
"Ventilation"
Ó
■
"Enable preheater bank electric 7D01"
"1"
■
"Enable reheater bank hydraulic 7D02"
"1"
■
"Enable humidity sensor 7D05"
"1"
■
"Enable CO2 sensor 7D06"
"1"
If applicable, adjust values (subject to design):
"Ventilation"
Ó
■
"Extract air temperature with standard ven-
tilation 7D08"
"100"
to
"300"
(
≙
10 to 30 °C)
■
"Flow rate reduced ventilation 7D0A"
"95"
up to
"7D0B"
minus
10 m
3
/h
■
"Flow rate nominal ventilation 7D0B"
"7D0A"
minus 10 m
3
/h up to
"7D0C"
minus 10 m
3
/h
■
"Flow rate intensive ventilation 7D0C"
"7D0B"
+ 10 m
3
/h up to
"280"
m
3
/h
Commissioning, inspection, maintenance
Further details regarding the individual steps
(cont.)
5623 661 GB
Service