140
Type AWT-AC
241.A04
241.A07
241.A10
241.A13
Connections
Heating water flow
mm
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Heating water return
mm
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Cu 28 x 1
Cold water
Rp
¾
¾
¾
¾
DHW
Rp
¾
¾
¾
¾
DHW circulation
G
1
1
1
1
Solar circuit flow
DN 20 pipe sleeve for multi connect system
Solar circuit return
DN 20 pipe sleeve for multi connect system
Condensate pipe (ex-
ternal unit)
mm
16 x 1
16 x 1
16 x 1
16 x 1
Liquid line
■ Pipe
7
mm
6 x 1
10 x 1
10 x 1
10 x 1
■ Internal unit
UNF
⅝
⅝
⅝
⅝
■ External unit
UNF
⁷
⁄
₁₆
⅝
⅝
⅝
Hot gas line
■ Pipe
7
mm
12 x 1
16 x 1
16 x 1
16 x 1
■ Internal unit
UNF
⅞
⅞
⅞
⅞
■ External unit
UNF
¾
⅞
⅞
⅞
Max. line length, liquid
line, hot gas line
m
20
30
30
30
Sound power level of the ex-
ternal unit
(Test with reference to
DIN EN 12102/
DIN EN ISO 9614-2)
Weighted sound power level
(total) at A7 °C (±3 K)/W35 °C
(±5 K)
■ At rated heating out-
put
dB(A)
60
62
62
63
Specification
Specification
(cont.)
5623 661 GB