134
Fault mes-
sage
Cause
Remedy
Re-
set-
ting
"305: Eng
under cur-
rent"
Generator current < 0.25 A
(20 s after connecting to the
mains).
Check connecting cable be-
tween the control unit PCB
and the capacitor.
Check whether the circuit
breaker has tripped. Reset if
it has.
Remove both cables from the
capacitor and check the re-
sistance across the Stirling
generator. This must be at
least 4 Ω. Observe safety in-
structions on page 61.
If the fault recurs, notify
Viessmann Technical Serv-
ice.
SR
"306: Mains
failure start
fault "
Generator voltage < 150 V
(5 s after start pulse).
AR
"307: En-
gine stall"
Generator voltage < 50 V (if
generator running).
AR
"308: Stop
resistor in-
tegrity"
Stop resistor test failed.
Check cables between the
control unit and the resis-
tors.
Check that the cables are
plugged in correctly. See
connection and wiring dia-
gram (plug X100) on
page 161.
Check resistors, replace if
necessary (see page 151).
AR
"309: Power
fail detec-
tion"
Software fault, mains failure
detection
Check electrical installation
on site.
If the fault recurs, check ca-
ble harnesses and plug-in
contacts in the control unit
and power supply unit.
AR
"310: Power
mon comm
fail"
Electricity meter communica-
tion fault
AR
"311: EGC
comm fail-
ure"
Communication fault
If the fault recurs or persists,
replace the control unit PCB
(see page 138).
AR
Troubleshooting
Fault messages
(cont.)
5618 294 GB
Summary of Contents for C3HA
Page 39: ...39 2 2x 1 Installation sequence Removing the front panel 5618 294 GB Installation ...
Page 42: ...42 1 2 Installation sequence Removing the transport brackets 5618 294 GB ...
Page 151: ...151 Checking and replacing resistors B C A Troubleshooting Repairs cont 5618 294 GB Service ...
Page 181: ...181 Parts lists Control unit assembly cont 5618 294 GB Service ...
Page 183: ...183 Parts lists Miscellaneous assembly cont 5618 294 GB Service ...
Page 191: ...191 5618 294 GB ...