105
"Burner sequence"
Function
Code
Operat-
ing level
Setting options
Delivered
condition
"Locking time min supp
bu"
3201
"F2"
0 to 40 min
15
"Advanced enable supp
bu DHW"
3203
"F2"
0 to 100 %
100
"Rel time min mod supp
bu"
3208
"F2"
0 to 255 min
15
"Rel integr mod supp
bu"
3209
"F2"
0 to 500 °C · min
100
"Release DHW charg-
ing"
3213
"F2"
■
"No restric-
tions"
■
"Stirling burn-
er only"
■
"First charg-
ing eng bu on-
ly"
■
"Fir'cha. eng
bu, supp bu
else"
"No restric-
tions"
"Supplementary source"
(see
page 155)
Function
Code
Operat-
ing level
Setting options
Delivered
condition
"Setpoint incr main
source"
3690
"F2"
0 to 10 °C
10
"Output limit main
source"
3691
"F2"
1 to 100 %
80
"With DHW charging"
3692
"F2"
■
"Locked"
■
"Substitute"
■
"Comple-
ment"
■
"Instantly"
"Substitute"
"Release below outside
temp"
3700
"F2"
-50 to 50 °C
- - -
"Release above outside
temp"
3701
"F2"
-50 to 50 °C
- - -
Codes
Changing codes
(cont.)
5618 294 GB
Service
Summary of Contents for C3HA
Page 39: ...39 2 2x 1 Installation sequence Removing the front panel 5618 294 GB Installation ...
Page 42: ...42 1 2 Installation sequence Removing the transport brackets 5618 294 GB ...
Page 151: ...151 Checking and replacing resistors B C A Troubleshooting Repairs cont 5618 294 GB Service ...
Page 181: ...181 Parts lists Control unit assembly cont 5618 294 GB Service ...
Page 183: ...183 Parts lists Miscellaneous assembly cont 5618 294 GB Service ...
Page 191: ...191 5618 294 GB ...