6.1
RS-232 Connection and
Port Configuration
To interface the VDP-80-720 with a home theater automation/control system or a PC running
terminal emulation software, connect it to your control system or PC as shown in Figure 3-7.
Configure the RS-232 controller or PC serial port as follows: no parity, 8 data bits, 1 stop bit
and no flow control. Set the baud rate 9600, to match that of the VDP-80-720 RS-232 port.
6.2
Serial Command Syntax
Table 6-1 lists the RS-232 command set. Command codes are in ASCII format and are
case-sensitive.
6
Serial Communications
Table 6-1. Serial Commands
ASCII
Remote
Function
%
ON
Power on
$
OFF
Power to standby
M
MENU
Activate on-screen menu
!
Force menu off
X
EXIT
Exit or cancel
k
OK
Accept command
<Enter>
OK
Accept command (uses the PC “ENTER” keycode)
<
Left arrow (“less-than“ key on keyboard)
>
Right arrow (“greater-than“ key on keyboard)
v
Down arrow (lower-case V)
^
Up arrow (<Shift>+6 key on keyboard)
0 - 9
0 - 9
Select input (0 = Input 10)
n
4:3
Select standard 4:3 aspect ratio; use previous zoom setting
[
Select standard 4:3 aspect ratio; no zoom
l
LETTERBOX
Select Letterbox aspect ratio (lower-case L); use previous
zoom setting
]
Select Letterbox aspect ratio; no zoom
w
16:9
Select 16:9 aspect ratio; use previous zoom setting
*
Select 16:9 aspect ratio; no zoom
j or /
I-Wide
Select IntelliWide aspect ratio
a
ISF Night
Recall settings from ISF Night image memory
b
ISF Day
Recall settings from ISF Day image memory
Summary of Contents for VDP-720
Page 2: ......
Page 10: ...List of Figures x Vidikron VDP 80 720 Owner s Operating Manual P R E L I M I N A R Y ...
Page 48: ...Operation 38 Vidikron VDP 80 720 Owner s Operating Manual P R E L I M I N A R Y Notes ...
Page 54: ...Specifications 44 Vidikron VDP 80 720 Owner s Operating Manual P R E L I M I N A R Y Notes ...
Page 55: ......