4.
With the hydraulic breather cap on top of
the hydraulic tank removed, insert the end
of the clear bleeder tube into the hydraulic
tank so the tube end is submerged in the
hydraulic fluid.
5.
Connect the tool to the proper power
s upply.
6.
Turn the power switch on the side of the
tool to the “ON” position. Turn the selector
switch on the side of the tool to the “JOG”
position.
WARNING
• The lower roll will rotate when the safety
foot switch is depressed.
• Avoid contact with the lower roll as it
rotates.
Failure to follow these instructions could
result in serious personal injury.
7.
Depress the safety foot switch and observe
the hydraulic fluid flowing through the clear
bleeder tube. The hydraulic fluid should contain
air bubbles. Continue running the fluid through
the bleeder tube for a minimum of five minutes.
During this time, lightly tap on all steel hydrau-
lic lines to free air that is trapped on the inside
walls. Manually pinch and release the hydraulic
hose several times to free trapped air inside the
cylinder. Rotate the selector valve to release
trapped air inside each line. After the hydraulic
fluid flows through the clear bleeder tube
without any air bubbles, continue running the
tool for a minimum of three minutes. Release
the safety foot switch.
8.
Remove the clear bleeder tube from the
tee fitting and hydraulic tank. Install the
plug into the tee fitting. Ensure that air is
not allowed back into the tee fit ting during
installation of the plug.