5.
Pull the emergency stop button and confirm
that power to the motor remains off. Depressing
the footswitch, pressing the enable button, or
adjusting the selector switch should have no
effect on the state of the tool. All components
should remain off.
WARNING
• The motor must not re-energize until
after the “ENABLE” button has been
pressed.
• If the motor energizes after an emergency
stop without first being enabled,
discontinue use and contact Victaulic.
Failure to follow this instruction could result
in serious personal injury or death.
6.
Press the “ENABLE” button.
7.
Depress the safety foot switch, confirm tool
operation, then release the safety foot switch.
8a.
Turn the selector switch on the side of the
tool to the “NORMAL” position. The tool head
should lower when the footswitch is depressed,
and rise to its resting position when the
footswitch is released.
8b.
Turn the selector switch on the side of
the tool to the “JOG” position. The tool head
should lower when the footswitch is depressed,
and remain in position when the footswitch is
released.
8c.
Turning the selector switch from “JOG” to
“NORMAL” with the head in a lowered position
should cause the head to rise to its resting
position.
9.
If the tool does not function as described,
refer to the “Troubleshooting” section.
TM-VE268_13
REV_H
TM-VE268
/ Operating and Maintenance Instructions Manual
Summary of Contents for VE268
Page 2: ......