3.
Depress the safety foot switch, observe the
lower roll’s rotational direction, then release the
safety foot switch.
4.
Proper rotation of the lower roll is
clockwise
when viewed from the front of the tool. If
rotation is clockwise, power hookup is complete.
5.
If rotation of the lower roll is
counterclockwise, turn the power switch on
the side of the tool to the “OFF” position and
proceed with the following steps.
WARNING
• Always turn off the main power supply
to the tool before making any tool
adjustments.
Failure to follow this instruction could result
in serious personal injury.
6a.
Lift and secure the lockout mechanism.
6b.
Turn off the main power supply to the tool
(main breaker panel, knife switch, etc.). Lock
the switch in the “OFF” position to prevent
accidental engagement.
NOTE:
Victaulic does not supply this lockout
mechanism.
7.
Reverse any two of the three power leads
at the power source.
8.
Turn on the main power supply to the tool
(main breaker panel, knife switch, etc.).
9.
Follow steps 1 to 3 to check rotational
direction of the lower roll. If rotational
direction is not clockwise, contact Victaulic.
If rotational direction is clockwise, the
power hookup procedure is complete.
TM-VE268_11
REV_H
TM-VE268
/ Operating and Maintenance Instructions Manual
Summary of Contents for VE268