FVAm™ Series Benchtop MPO Autofocus Microscope User Guide
22132675 Rev. 101, Standard, 3-2
Performing Pass/Fail tests and working with saved test results
Requirements for Pass/Fail tests
Requirements for Pass/Fail tests
Pass/Fail tests inspect fiber connectors against preconfigured pass criteria for the active analysis profile. You can
start a Pass/Fail test from either FiberChekPRO or, if available, the onboard controls on the FVAm microscope.
Notes:
•
A Pass or Fail result applies to the entire connector. If only one fiber in the array fails to meet the preconfig-
ured pass criteria, the test will return a Fail result for the entire connector. To achieve a Pass result, every fiber
in the array must meet the pass criteria.
•
For information about viewing the pass criteria for analysis profiles, refer to the
FiberChekPRO Automated
Fiber Inspection and Analysis Software User Manual
, which you can access from the FiberChekPRO
Help
menu.
•
For information about using the touchscreen and onboard controls, see
“Touchscreen display module and
onboard controls” on page 2-12
.
Table 3-1: Before you begin a Pass/Fail test
Ensure that...
See...
A fiber connector or transceiver module (QSFP of CFP) with an MT
ferrule is properly connected to the microscope.
•
“Mounting and positioning an adapter” on
page 2-7
•
“Connecting fiber connectors and transceiver
modules” on page 2-9
A live image of the fiber connector is displayed on either the
FiberChekPRO
Inspection
page or, if available, the touchscreen.
•
“Connecting to FiberChekPRO” on page 2-11
•
“Focus-quality meter” on page 2-14
•
“Panning and auto-focusing in live view” on
page 2-16
The Pass/Fail test is set up.
Note:
When necessary, you can edit the optical setting to better suit
fiber connectors to be tested. See
“Editing the active optical setting”
“Setting up Pass/Fail tests” on page 2-19
User information you want to appear on generated reports has been
added.
“Adding user information” on page 2-21
If required, the group that you want to add saved results to is active
on the FVAm microscope.