dPMR Signal Rx Meter Remote Commands
4 - 24
4.10.8
Symbol Deviation - Upper Limit Value
:LIMits:SYMdev:CH1:UPPer:VALue
:LIMits:SYMdev:CH1:UPPer:VALue?
Description:
Set command defines Upper Limit Value for Symbol Deviation measurement.
Query command returns parameter setting.
Range:
0.0 to 10,000.0 Hz
Units:
Hz
Default Value:
0.0 Hz
Set/Query Format:
NRf | NR2
Example:
:LIMits:SYMdev:CH1:UPPer:VALue 500Hz
Sets Upper Limit Value for Symbol Deviation measurement to 500.0 Hz.
Query Response:
:LIMits:SYMdev:CH1:UPPer:VALue?
500.00